At 05:22 μμ 28/2/2000 +0000, you wrote:
It occured to me last night what the problem is. The -ev option is
returning a number with a higher precision than the -ea option is using.
The -ea option, instead of truncating the value (which it should do) is
rounding the value to the lower precision. In approx. 50% of cases of
using the output of the -ev option as the input of the -ea option, this
will cause clipping of the waveform.

Example:
1. -ev option returns 105.92875
2. this value fed into -ea option
3. -ea option rounds the input value to 105.93
4. since amplify-% now exceeds the maximum, clipping will occur

I hope this is helpful to you. For my part, I will just truncate the
value myself before passing it to the -ea option. Does
ecatools_normalize take this situation into account?

CT

--
Christopher Taylor <chris@thedial.com>  theDial
Director of Research and Development    http://www.thedial.com/
3131 Elliott Ave, Suite 750             phone: (206) 352-8200 x2002