On Sun, Apr 15, 2012 at 11:20:59PM +0300, Kai Vehmanen wrote:
> Hi,
>
> On Sun, 15 Apr 2012, S. Massy wrote:
>
> >One nice feature of sox is its clip monitoring ability: as it processes
> >data, it will issue a warning when a sample is clipped and a total count
> >of such occurences at the end. Now, ecasignalview does something like
>
> you should be able to do this with a combination of "-evp" and
> "-ev". These are what ecasignalview uses internally. "-evp" can
> provide immediate feedback while "-ev" maintains the stats for the
> whole run.
Thanks! What is the meaning of the last value? It always seems to be 0.
Cheers,
s.M.
-- ------------------------------------------------------------------------------ For Developers, A Lot Can Happen In A Second. Boundary is the first to Know...and Tell You. Monitor Your Applications in Ultra-Fine Resolution. Try it FREE! http://p.sf.net/sfu/Boundary-d2dvs2 _______________________________________________ Ecasound-list mailing list Ecasound-list@email-addr-hidden https://lists.sourceforge.net/lists/listinfo/ecasound-listReceived on Mon Apr 16 04:15:01 2012